Skip to main content

Zhengzhou Jiarun Instrument & Equipment Co., Ltd.

Laboratory Solutions

From Process Requirements to Complete Laboratory Systems

We provide integrated laboratory equipment solutions for solvent evaporation, reaction, temperature control, vacuum and drying processes, helping you configure a suitable system according to your specific application.

Tell Us Your Application →
01 Process Analysis
02 System Configuration
03 Equipment Supply
04 Customizable Solutions
05 Technical Support
JIARUN Complete Laboratory System
01

Solvent Evaporation & Recovery Solution

A complete laboratory solution for solvent removal, concentration and solvent recovery.

Typical Process Flow

Sample / Solvent

Plant extracts, essential oils, chemical samples, etc.

Evaporation

Evaporation under reduced pressure.

Condensation

Vapor is cooled by the condenser.

Collection

Collected / recovered solvent.

System Configuration & Connection

CCA-420 Low Temperature Chiller

Low Temperature Chiller

Provides circulating coolant to the condenser.

Electric Lift Rotary Evaporator

Rotary Evaporator

Evaporation and concentration.

Circulating Water Vacuum Pump

Circulating Water Vacuum Pump

Provides vacuum for the system.

Cooling circuit: Low Temperature Chiller → Rotary Evaporator Condenser    |    Vacuum connection: Vacuum Pump → Rotary Evaporator System

Key Applications

  • Essential oil extraction
  • Solvent concentration
  • Solvent recovery
  • Chemical research
  • Natural product research

Information Needed for Selection

  • Sample / solvent
  • Expected working volume
  • Boiling point, if known
  • Target temperature
  • Vacuum requirement
  • Other process requirements
02

Reaction & Temperature Control Solution

Temperature-controlled solutions for chemical synthesis, mixing and process development.

System Configuration

Heating and Cooling Circulator

Heating & Cooling Circulator

Temperature-controlled circulation.

Double Layer Glass Reactor

Glass Reactor

1–5L / 10–50L / 5–200L

Stainless Steel Reactor

Stainless Steel Reactor

Multiple capacities available.

Temperature-controlled circulation: Heating & Cooling Circulator ⇄ Reactor Jacket
Final equipment configuration depends on working capacity, temperature range, material properties and process requirements.

Key Applications

  • Chemical synthesis
  • Material research
  • Pharmaceutical R&D
  • Catalyst research
  • Mixing and reaction
  • Process development

Information Needed for Selection

  • Reaction volume
  • Temperature range
  • Material requirements
  • Stirring requirements
  • Vacuum requirement, if needed
  • Other process requirements
03
Laboratory Vacuum Solution

Circulating Water Vacuum System

Circulating water vacuum systems for rotary evaporation and compatible laboratory processes.

Typical Applications

  • Rotary evaporation
  • Laboratory vacuum
  • Vacuum-assisted processes
  • Compatible laboratory systems

System Features

  • Circulating water vacuum system
  • Laboratory vacuum applications
  • Compatible with rotary evaporation systems
  • Multiple model options
04
Freeze Drying Solution

Low-Temperature Drying for Heat-Sensitive Materials

Freeze drying solutions for laboratory samples requiring low-temperature drying and moisture removal.

When to Consider Freeze Drying

  • Heat-sensitive samples
  • Low-temperature drying applications
  • Biological or pharmaceutical research samples
  • Plant extract research

Configuration Considerations

  • Required capacity
  • Tray configuration
  • Application requirements
  • Other process requirements
05
Spray Drying Solution

Liquid-to-Powder Laboratory Spray Drying

Convert liquid samples into powder through laboratory spray drying.

When to Consider Spray Drying

  • Liquid-to-powder processing
  • Powder preparation research
  • Formulation research
  • Material development

Configuration Considerations

  • Feed material
  • Process parameters
  • Atomizer options
  • Drying configuration
  • Other process requirements
Equipment Selection

Equipment Selection Based on Your Process

Equipment configuration is determined according to your actual process conditions rather than by model number alone.

Working Capacity
Temperature Range
Vacuum Requirement
Material / Solvent
Process Type
Solution Process

How to Get Your Laboratory Solution

Tell us your process requirements and we will help you configure suitable laboratory equipment.

01

Tell Us Your Application

Tell us your sample, process, working capacity and expected result.

02

Confirm Requirements

Confirm working volume, temperature, vacuum, material and other requirements.

03

Equipment Selection

Select suitable equipment models, configurations and system combinations.

04

Equipment Preparation & Delivery

Equipment preparation, inspection, packaging and shipment.

Customizable Laboratory Solutions

System configurations can be adapted according to your working capacity, temperature range, vacuum requirements, material properties and process conditions.

Equipment Configuration
System Combination
Custom Specifications
Special Process Requirements