Skip to main content

Zhengzhou Jiarun Instrument & Equipment Co., Ltd.

Laboratory Temperature Control

Heating & Cooling Circulator

The GDFB Series provides integrated heating and cooling circulation for laboratory reactors and process equipment, supporting controlled temperature operation across a wide working range.

°C
-80°C to 200°C Temperature range
±1
±1°C Control accuracy
↻
30 L/min Circulation flow
Request a Quote →
GDFB Heating and Cooling Circulator
Product Structure

Main Structure and Components

The GDFB Series integrates digital temperature control, circulation connections, liquid-level monitoring and heat-dissipation components into one temperature-control unit.

GDFB Heating and Cooling Circulator Structure

Key Features

1
Vacuum Gauge System operating indication
2
Liquid Level Sight Glass Convenient liquid-level observation
3
Digital Controller Temperature monitoring and control
4
External Circuit Connection Connection to reactor jacket or process equipment
5
Heat Dissipation Vents Three-side ventilation structure
6
Universal Casters Wheels with brake for convenient positioning
Technical Specifications

Technical Parameters

Compare the GDFB 10 Series and 20 Series according to required low-temperature capability and tank capacity.

GDFB 10 Series · 6L Tank
Specification GDFB-10/30 GDFB-10/40 GDFB-10/80
Temperature Range -30°C to 200°C -40°C to 200°C -80°C to 200°C
Control Accuracy ±1°C
Tank Capacity 6L
Circulation Flow 30 L/min
Lift Head 15 m
Circulation Power 0.25 kW
Sensor PT100
Power Supply 220V / 50Hz
GDFB 20 Series · 11L Tank
Specification GDFB-20/30 GDFB-20/40 GDFB-20/80
Temperature Range -30°C to 200°C -40°C to 200°C -80°C to 200°C
Control Accuracy ±1°C
Tank Capacity 11L
Circulation Flow 30 L/min
Lift Head 15 m
Circulation Power 0.25 kW
Sensor PT100
Power Supply 220V / 50Hz 220V / 50Hz 380V / 50Hz
Complete Reaction System

Build a Complete Temperature-Controlled Reaction System

Combine the GDFB heating & cooling circulator with a reactor and vacuum system to build a complete laboratory reaction configuration.

Glass Reactor
Glass Reactor
SF212 Series
Reaction and mixing
+
GDFB Heating and Cooling Circulator
Heating & Cooling
Circulator
Temperature control
+
Circulating Water Vacuum Pump
Vacuum
System
Reduced-pressure operation

Need Help Selecting a GDFB Model?

Tell us your reactor capacity, target temperature and process requirements. We can help you select a suitable heating and cooling configuration.

✉
Get a Quote
?
Technical Support
⚙
Model Selection